Explore Our New Support Portal!

Stay tuned as we continue to add new materials, training content, and valuable updates to help you get the most out of your Absolute Haitian experience.

VISIT SUPPORT PORTAL

How to Remove and Clean Suction Strainers

How-To Guides & Resources

This guide provides step-by-step instructions on removing and cleaning suction strainers and magnets on Haitian Mars (MA) and Jupiter (JU) injection molding machines. Proper maintenance ensures hydraulic system efficiency and prevents contamination-related failures.

The Suction Strainer Removal Guide outlines:

Safety First – Turning off the main power disconnect and locking out the machine
Accessing the Strainer – Locating the suction strainer housing inside the oil tank
Removing the Strainer – Using a 10mm hex key or screwdriver to disengage the cover and prevent oil leakage
Cleaning the Strainer and Magnet – Washing components in a cleaning tank and removing any metallic debris
Reinstalling the Strainer – Reassembling in reverse order to ensure proper sealing and function

This guide is a must-have for field service personnel and machine operators, helping maintain optimal oil filtration and hydraulic system performance.